Попытка упорядочить свои заметки, касающиеся строительства своего дома (загородного).
Динамика роста тарифов на услуги ЖКХ и инфляции | ||||||
Год | Отопление (руб./кв. м общей площади) |
Горячее водоснабжение (руб./чел.) |
Холодное водоснабжение (руб./чел.) |
Газ (руб./чел.) |
Электроэнергия (коп./кВт/ч) | Инфляция (%) |
2001 | 2,60 | 47,60 | 44,84 | 4,70 | 63 | 18,6 |
2002 | 3,30 | 61,20 | 50,70 | 6,50 | 90 | 15,1 |
2003 | 4,20 | 77,30 | 68,40 | 8,20 | 105 | 12 |
2004 | 4,90 | 89,70 | 95,80 | 9,90 | 122 | 11,7 |
2005 | 6,70 | 123,80 | 133,0 | 11,90 | 153 | 10,9 |
2006 | 8,40 | 191,60 | 54,40 / 76,30 водоотведение | 14,10 | 184 | 9,0 |
2007 | 9,90 | 228,70 | 67,80 / 90,90 | 15,90 | 208 | 11,9 |
2008 | 11,80 | 272,90 | 81,84 / 106,28 | 19,40 | 237 | 13,3 |
2009 | 15,30 | 354,30 | 107,15 / 132,57 | 24,30 | 301 | Прогноз 12 |
2010 | 19,04 | 444,06 | 137,86 / 168,19 | 29,04 | 345 | — |
Повышение за 9 лет (в среднем) | в 7 раз или на 600% | в 9 раз или на 800% | в 6 раз или на 500% | в 5 раз или на 400% | в 5 раз или на 400% | Рост инфляции 115 % |
По данным РЭК г. Москвы и информационно-аналитического портала Индустрии управления активами фондов подробнее |
S=Sg*µ
Sg - расчётное значение веса снегового покрова на 1м2 горизонтальной поверхности. В Санкт-Петербурге (третий снеговой район) расчетный вес снегового покрова при расчете снеговой нагрузки на кровлю - 180 кг на кв. метр.
Снеговой район | I | II | III | IV | V | VI | VII | VIII |
Sg (кгс/м2) | 80 | 120 | 180 | 240 | 320 | 400 | 480 | 560 |
µ - коэффициент перехода от веса снегового покрова земли к снеговой нагрузке на покрытие.
Коэффициент µ зависит от угла наклона ската кровли:
µ=1 при углах наклона ската кровли меньше 25°.
µ=0,7 при углах наклона ската кровли от 25 до 60°.
При углах наклона ската кровли более 60° значение µ в расчёте полной снеговой нагрузки не учитывают.
Таблица сравнения характеристик пассивного дома с принятыми сейчас строительными нормами (британскими).
Стандарт пассивного дома | Принятые нормы строительства (UK) | |
Компактная форма и хорошая изоляция: | Все элементы внешней оболочки ПД изолированы для обеспечения значений параметра U не превышающих 0.15 W/m2/K | Ограничения возможных значений U в диапазоне 0.25-0.35 W/m2/K |
Ориентация относительно юга и учет расположение теней: | Пассивное использование солнечной энергии является существенным фактором при проектировании ПД. | Some consideration is given with regard to north/south orientation, but the improved energy savings resulting from passive site design are often overlooked. |
Energy-efficient window glazing and frames: | Windows should have U-values not exceeding 0.80 W/m².K for both glazing and frames - this requires the window frame to incorporate insulation and the glazing to be tripple. Solar Heat Gain Co-efficient through the glazing should be at least 50%1. | 1.8-2.2 W/m2K typical |
Building envelope air-tightness: | Air leakage (n50) through unwanted gaps and cracks in the building fabric must be less than 0.6 times the house volume per hour under negative and positive pressurisation. | Design air permeability of 7 to 10 m2/hr/m3@ 50 Pa. This is approximately a factor of 10 poorer than the PassivHaus standard. Research has also shown that air permeability values for completed dwellings frequently exceed these design limits. |
Passive preheating of fresh air: | Fresh air may be brought into the house through underground ducts that exchange heat with the soil. This preheats fresh air to a temperature above 5°C (41°F), even on cold winter days. | The majority of new-builds do not achieve good enough air permeability values to warrant the incorporation of a whole house ventilation system - thus trickle vents, extract fans, or passive stack ventilation is commonly used. |
Highly efficient heat recovery from exhaust air using an air-to-air heat exchanger: | Most of the perceptible heat in the exhaust air is transferred to the incoming fresh air (heat recovery rate over 80%). | |
Energy-saving household appliances: | Low energy refrigerators, stoves, freezers, lamps, washers, dryers, etc. are indispensable in a PassivHaus. | Dedicated low-energy lights are provided in a number of rooms in a new dwelling - if appliances are supplied they will be generally C-rated or perhaps 'Energy Saving Recommended' in some instances (as these are widely available). |
Total energy demand for space heating and cooling | Less than 15 kWh/m2/yr | Typically 55 kWh/m2/yr |
1The Solar Heat Gain Co-efficient (SHGC) is provided as a guide, it can be adjusted for glazing on different facades. This can help either reduce heat loss on sheltered sides/ north facing glazing, or alternatively help to reduce the likelihood of overheating when specified in conjunction with other features/strategies (please note that the SHGC of a window usually decreases as the U-value improves).
A2 Building designers and plans (Regulations and guidelines 2002)
...
...
B3 Foundations (Regulations and guidelines 2004)
...
...
C3Thermal insulation in a building (unofficial translation2003, вольный перевод на русский)
C4 Thermal insulation (unofficial translation2003)
...
D2 Indoor climate and ventilation of buildings (unofficial translation)
...
E1 Stuctural fire safety in buildings (unofficial translation - 2002)
E2 Fire safety of production and warehouse buildings (unofficial translation - 2005)
...
E4 Fire safety of garages (unofficial translation2005)
E7 Fire safety of ventilation installations (unofficial translation2004)
...
E9 Fire safety of boiler rooms and fuel stores (unofficial translation2005)
F1 Barrier-free building (unofficial translation2005)
...
G1 Housing design (unofficial translation2005)
...